Skip to content

Outages

This page provides detailed information about outages-related parameter classes.

entsoe.Outages

ENTSO-E Outages parameter classes.

This module contains parameter classes for ENTSO-E Outages endpoints, providing easy-to-use interfaces for different outage data types based on the ENTSO-E Transparency Platform API specification.

AggregatedUnavailabilityOfConsumptionUnits

AggregatedUnavailabilityOfConsumptionUnits(
    bidding_zone_domain: str,
    period_start: Optional[int] = None,
    period_end: Optional[int] = None,
    period_start_update: Optional[int] = None,
    period_end_update: Optional[int] = None,
    business_type: Optional[str] = None,
    offset: int = 0,
)

Bases: Outages

Parameters for 7.1.A-B Aggregated Unavailability of Consumption Units.

Data view: https://transparency.entsoe.eu/outage-domain/r2/unavailabilityInTransmissionGrid/show

Fixed parameters:

  • documentType: A76 (Load unavailability)

Notes: - Returns aggregated unavailability data for consumption units - Can be filtered by business type (A53=Planned maintenance, A54=Forced unavailability) - Period parameters are optional if PeriodStartUpdate/PeriodEndUpdate are defined

Initialize aggregated unavailability of consumption units parameters.

Parameters:

  • bidding_zone_domain (str) –

    EIC code of Control Area or Bidding Zone

  • period_start (Optional[int], default: None ) –

    Start period (YYYYMMDDHHMM format, optional if period_start_update defined)

  • period_end (Optional[int], default: None ) –

    End period (YYYYMMDDHHMM format, optional if period_end_update defined)

  • period_start_update (Optional[int], default: None ) –

    Start of update period (YYYYMMDDHHMM format)

  • period_end_update (Optional[int], default: None ) –

    End of update period (YYYYMMDDHHMM format)

  • business_type (Optional[str], default: None ) –

    Business type (A53=Planned maintenance, A54=Forced unavailability)

  • offset (int, default: 0 ) –

    Offset for pagination

Fallbacks

Fallbacks(
    process_type: str,
    business_type: str,
    bidding_zone_domain: str,
    period_start: Optional[int] = None,
    period_end: Optional[int] = None,
    period_start_update: Optional[int] = None,
    period_end_update: Optional[int] = None,
    doc_status: Optional[str] = None,
    m_rid: Optional[str] = None,
    offset: int = 0,
)

Bases: Outages

Parameters for Fall-backs [IFs IN 7.2, mFRR 3.11, aFRR 3.10].

Data view: https://transparency.entsoe.eu/outage-domain/r2/unavailabilityInTransmissionGrid/show

Fixed parameters:

  • documentType: A53 (Outage publication document)

Required parameters: - processType: A47 (Manual frequency restoration reserve), A51 (Automatic frequency restoration reserve), A63 (Imbalance Netting) - businessType: C47 (Disconnection), A53 (Planned maintenance), A54 (Unplanned outage), A83 (Auction cancellation)

Notes: - Returns fall-back data for frequency restoration reserves and imbalance netting - Both processType and businessType are mandatory for this endpoint - Period parameters are optional if PeriodStartUpdate/PeriodEndUpdate are defined

Initialize fall-backs parameters.

Parameters:

  • process_type (str) –

    Process type (A47=Manual frequency restoration reserve, A51=Automatic frequency restoration reserve, A63=Imbalance Netting)

  • business_type (str) –

    Business type (C47=Disconnection, A53=Planned maintenance, A54=Unplanned outage, A83=Auction cancellation)

  • bidding_zone_domain (str) –

    EIC code of a CTA/LFA/REG

  • period_start (Optional[int], default: None ) –

    Start period (YYYYMMDDHHMM format, optional if period_start_update defined)

  • period_end (Optional[int], default: None ) –

    End period (YYYYMMDDHHMM format, optional if period_end_update defined)

  • period_start_update (Optional[int], default: None ) –

    Start of update period (YYYYMMDDHHMM format)

  • period_end_update (Optional[int], default: None ) –

    End of update period (YYYYMMDDHHMM format)

  • doc_status (Optional[str], default: None ) –

    Document status (A13=Withdrawn, by default withdrawn publications not returned)

  • m_rid (Optional[str], default: None ) –

    Message ID for specific publication versions

  • offset (int, default: 0 ) –

    Offset for pagination

UnavailabilityOfGenerationUnits

UnavailabilityOfGenerationUnits(
    bidding_zone_domain: str,
    period_start: Optional[int] = None,
    period_end: Optional[int] = None,
    period_start_update: Optional[int] = None,
    period_end_update: Optional[int] = None,
    business_type: Optional[str] = None,
    doc_status: Optional[str] = None,
    registered_resource: Optional[str] = None,
    m_rid: Optional[str] = None,
    offset: int = 0,
)

Bases: Outages

Parameters for 15.1.A&B Unavailability of Generation Units.

Data view: https://transparency.entsoe.eu/outage-domain/r2/unavailabilityInTransmissionGrid/show

Fixed parameters:

  • documentType: A80 (Generation unavailability)

Notes: - Returns generation unit unavailability data - Can be filtered by business type (A53=Planned maintenance, A54=Forced unavailability) - Supports update-based queries with PeriodStartUpdate/PeriodEndUpdate

Initialize unavailability of generation units parameters.

Parameters:

  • bidding_zone_domain (str) –

    EIC code of Control Area, Bidding Zone

  • period_start (Optional[int], default: None ) –

    Start period (YYYYMMDDHHMM format)

  • period_end (Optional[int], default: None ) –

    End period (YYYYMMDDHHMM format)

  • period_start_update (Optional[int], default: None ) –

    Start of update period (YYYYMMDDHHMM format)

  • period_end_update (Optional[int], default: None ) –

    End of update period (YYYYMMDDHHMM format)

  • business_type (Optional[str], default: None ) –

    Business type (A53=Planned maintenance, A54=Forced unavailability)

  • doc_status (Optional[str], default: None ) –

    Document status (A05=Active, A09=Cancelled, A13=Withdrawn)

  • registered_resource (Optional[str], default: None ) –

    EIC Code of Generation Unit

  • m_rid (Optional[str], default: None ) –

    Message ID for specific outage versions

  • offset (int, default: 0 ) –

    Offset for pagination

UnavailabilityOfOffshoreGridInfrastructure

UnavailabilityOfOffshoreGridInfrastructure(
    bidding_zone_domain: str,
    period_start: Optional[int] = None,
    period_end: Optional[int] = None,
    period_start_update: Optional[int] = None,
    period_end_update: Optional[int] = None,
    doc_status: Optional[str] = None,
    m_rid: Optional[str] = None,
    offset: int = 0,
)

Bases: Outages

Parameters for 10.1.C Unavailability of Offshore Grid Infrastructure.

Data view: https://transparency.entsoe.eu/outage-domain/r2/unavailabilityInTransmissionGrid/show

Fixed parameters:

  • documentType: A79 (Offshore grid infrastructure unavailability)

Notes: - Returns offshore grid infrastructure unavailability data - Period parameters are optional if PeriodStartUpdate/PeriodEndUpdate are defined - No BusinessType parameter available for this endpoint

Initialize unavailability of offshore grid infrastructure parameters.

Parameters:

  • bidding_zone_domain (str) –

    EIC code of Control Area, Bidding Zone

  • period_start (Optional[int], default: None ) –

    Start period (YYYYMMDDHHMM format, optional if period_start_update defined)

  • period_end (Optional[int], default: None ) –

    End period (YYYYMMDDHHMM format, optional if period_end_update defined)

  • period_start_update (Optional[int], default: None ) –

    Start of update period (YYYYMMDDHHMM format, mandatory if period_start/end not defined)

  • period_end_update (Optional[int], default: None ) –

    End of update period (YYYYMMDDHHMM format, mandatory if period_start/end not defined)

  • doc_status (Optional[str], default: None ) –

    Document status (A05=Active, A09=Cancelled, A13=Withdrawn)

  • m_rid (Optional[str], default: None ) –

    Message ID for specific outage versions

  • offset (int, default: 0 ) –

    Offset for pagination

UnavailabilityOfProductionUnits

UnavailabilityOfProductionUnits(
    bidding_zone_domain: str,
    period_start: Optional[int] = None,
    period_end: Optional[int] = None,
    period_start_update: Optional[int] = None,
    period_end_update: Optional[int] = None,
    business_type: Optional[str] = None,
    doc_status: Optional[str] = None,
    registered_resource: Optional[str] = None,
    m_rid: Optional[str] = None,
    offset: int = 0,
)

Bases: Outages

Parameters for 15.1.C-D Unavailability of Production Units.

Data view: https://transparency.entsoe.eu/outage-domain/r2/unavailabilityInTransmissionGrid/show

Fixed parameters:

  • documentType: A77 (Production unit unavailability)

Notes: - Returns production unit unavailability data - Can be filtered by business type (A53=Planned maintenance, A54=Forced unavailability) - Supports update-based queries with PeriodStartUpdate/PeriodEndUpdate

Initialize unavailability of production units parameters.

Parameters:

  • bidding_zone_domain (str) –

    EIC code of Control Area, Bidding Zone

  • period_start (Optional[int], default: None ) –

    Start period (YYYYMMDDHHMM format)

  • period_end (Optional[int], default: None ) –

    End period (YYYYMMDDHHMM format)

  • period_start_update (Optional[int], default: None ) –

    Start of update period (YYYYMMDDHHMM format)

  • period_end_update (Optional[int], default: None ) –

    End of update period (YYYYMMDDHHMM format)

  • business_type (Optional[str], default: None ) –

    Business type (A53=Planned maintenance, A54=Forced unavailability)

  • doc_status (Optional[str], default: None ) –

    Document status (A05=Active, A09=Cancelled, A13=Withdrawn)

  • registered_resource (Optional[str], default: None ) –

    EIC Code of Production Unit

  • m_rid (Optional[str], default: None ) –

    Message ID for specific outage versions

  • offset (int, default: 0 ) –

    Offset for pagination

UnavailabilityOfTransmissionInfrastructure

UnavailabilityOfTransmissionInfrastructure(
    out_domain: str,
    in_domain: str,
    period_start: Optional[int] = None,
    period_end: Optional[int] = None,
    period_start_update: Optional[int] = None,
    period_end_update: Optional[int] = None,
    time_interval_update: Optional[str] = None,
    business_type: Optional[str] = None,
    doc_status: Optional[str] = None,
    m_rid: Optional[str] = None,
    offset: int = 0,
)

Bases: Outages

Parameters for 10.1.A&B Unavailability of Transmission Infrastructure.

Data view: https://transparency.entsoe.eu/outage-domain/r2/unavailabilityInTransmissionGrid/show

Fixed parameters:

  • documentType: A78 (Transmission unavailability)

Notes: - Returns transmission infrastructure unavailability data - Uses Out_Domain and In_Domain instead of BiddingZone_Domain - Supports TimeIntervalUpdate as alternative to PeriodStartUpdate/PeriodEndUpdate - Can be filtered by business type (A53=Planned maintenance, A54=Forced unavailability)

Initialize unavailability of transmission infrastructure parameters.

Parameters:

  • out_domain (str) –

    EIC code of Control Area or Bidding Zone (output domain)

  • in_domain (str) –

    EIC code of Control Area or Bidding Zone (input domain)

  • period_start (Optional[int], default: None ) –

    Start period (YYYYMMDDHHMM format)

  • period_end (Optional[int], default: None ) –

    End period (YYYYMMDDHHMM format)

  • period_start_update (Optional[int], default: None ) –

    Start of update period (YYYYMMDDHHMM format)

  • period_end_update (Optional[int], default: None ) –

    End of update period (YYYYMMDDHHMM format)

  • time_interval_update (Optional[str], default: None ) –

    Can be used instead of PeriodStartUpdate & PeriodEndUpdate

  • business_type (Optional[str], default: None ) –

    Business type (A53=Planned maintenance, A54=Forced unavailability)

  • doc_status (Optional[str], default: None ) –

    Document status (A05=Active, A09=Cancelled, A13=Withdrawn)

  • m_rid (Optional[str], default: None ) –

    Message ID for specific outage versions

  • offset (int, default: 0 ) –

    Offset for pagination